BlogsAsk The Experts ForumHow Was the PW Duration (Pulse-off Duration) of PIE Fixed in EPC Class 1 Gen 2 Reader-to-Tag Communication?

How Was the PW Duration (Pulse-off Duration) of PIE Fixed in EPC Class 1 Gen 2 Reader-to-Tag Communication?

Posted By RFID Journal, 11.09.2012
Please provide some information about this.

—Name withheld

———
To answer your question, I reached out to the engineers at Impinj, a provider of ultrahigh-frequency (UHF) Gen 2 RFID technology. Here is the response I received:

"The signal goes low for 50 percent of the time during a 'DATA 0' and 25 percent of the time for a 'DATA 1.' The signal is the energy traveling from the reader to the tag. As you know, this is an RF carrier with modulated data. This data is sent in a string of 'ones' (1) and 'zeros' (0). For a 'one,' the RF carrier is only modulated 25 percent of the symbol time which is referenced to the TARI (type A reference interval). For a 'zero,' the carrier is modulated 50 percent of the symbol time. The illustration below, taken from page 24 of the EPC spec sheet, shows this pretty clearly."




—Mark Roberti, Founder and Editor,
RFID Journal

Login and post your comment!

Not a member?

Signup for an account now to access all of the features of RFIDJournal.com!

Next Post
How Can I Find Partners for Providing VA...
Previous Post
How Can I Learn About RTLS Technology?
PREMIUM CONTENT
Case Studies Features Best Practices How-Tos
RFID JOURNAL EVENTS
Live Events Virtual Events Webinars
ASK THE EXPERTS
Simply enter a question for our experts.
TAKE THE POLL
JOIN THE CONVERSATION ON TWITTER
Loading
RFID Journal LIVE! RFID in Health Care LIVE! LatAm LIVE! Brasil LIVE! Europe RFID Connect Virtual Events RFID Journal Awards Webinars Presentations
© Copyright 2002-2016 RFID Journal LLC.
Powered By: Haycco